Review



horizontal pipette puller p-97  (Sutter Instrument Company)


Bioz Verified Symbol Sutter Instrument Company is a verified supplier
Bioz Manufacturer Symbol Sutter Instrument Company manufactures this product  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 90

    Structured Review

    Sutter Instrument Company horizontal pipette puller p-97
    Horizontal Pipette Puller P 97, supplied by Sutter Instrument Company, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/horizontal+pipette+puller+p-97/micropipette+puller+p+97/bio_rxiv__2025__07__08__662991-203-21-25
    Average 90 stars, based on 1 article reviews
    horizontal pipette puller p-97 - by Bioz Stars, 2026-09
    90/100 stars

    Images

    Related Articles

    Patch Clamp:

    Article Title: Sparsening and decorrelation of granule cell activity in the dentate gyrus by noradrenaline
    Article Snippet: Fluorescently labeled interneurons were identified with an Andor DSD2 confocal unit (Oxford Instruments). .. Pipettes for patch-clamp recordings were fabricated from thick-walled borosilicate glass capillaries (outer diameter: 2 mm, inner diameter: 1.16 mm) with a horizontal pipette puller (P-97, Sutter Instruments). ..

    Article Title: ATAD1 Regulates Neuronal Development and Synapse Formation Through Tuning Mitochondrial Function.
    Article Snippet: Cultured rat hippocampal neurons were visualized with 40× water-immersion objective on an upright microscope (BX51WI, Olympus, Tokyo, Japan), with interference contrast (IR/DIC) and an infrared camera connected to the video monitor. .. For whole-cell patch-clamp, patch pipettes were pulled to a resistance of 6–8 MΩ by horizontal pipette puller (P-97, Sutter Instruments, Novato, CA, USA). ..

    Transferring:

    Article Title: Sparsening and decorrelation of granule cell activity in the dentate gyrus by noradrenaline
    Article Snippet: Fluorescently labeled interneurons were identified with an Andor DSD2 confocal unit (Oxford Instruments). .. Pipettes for patch-clamp recordings were fabricated from thick-walled borosilicate glass capillaries (outer diameter: 2 mm, inner diameter: 1.16 mm) with a horizontal pipette puller (P-97, Sutter Instruments). ..

    Article Title: Enhanced Rap1 small GTPase activity in the ventral hippocampus drives stress-induced anxiety
    Article Snippet: The temperature of ACSF in the chamber was maintained at 29 ± 1°C using an automatic temperature controller (TC-324B, Warner Instruments Co., Hamden, US). .. Recording patch pipettes were made from filamented borosilicate glass capillary tubes (inner diameter, 0.84 mm) by using a horizontal pipette puller (P-97; Sutter Instrument Co., Novato, US). ..

    Article Title: Low-intensity ultrasound activates transmembrane chloride flow through CFTR.
    Article Snippet: .. The glass pipette with a resistance of 3–5 MΩ was pulled by a horizontal pipette puller (P-97, Sutter Instrument, USA). .. Then, the glass pipette was moved close to bath solution in the recording chamber via a three-dimensional micromanipulator (MP-285, Sutter Instrument, USA).

    Article Title: Input‐specific bidirectional regulation of hippocampal CA3 pyramidal cell excitability
    Article Snippet: .. Patch pipettes were pulled from borosilicate glass tubing (outer diameter: 1.5 mm, wall thickness: 0.225 mm) using a horizontal pipette puller (P-97, Sutter Instruments, Novato, CA, USA) and were filled with the intracellular solution containing 130 K-gluconate, 7 KCl, 1 MgCl2, 2 Mg-ATP, 0.3 Na-GTP, 10 Hepes, 0.1 EGTA (in mm; pH adjusted to 7.20 with KOH, 295 mOsm). ..

    Article Title: Synergism between two BLA-to-BNST pathways for appropriate expression of anxiety-like behaviors in male mice.
    Article Snippet: The temperature of ASCF was maintained at 29 ± 1 °C with an automatic temperature controller (TC-324B, Warner Instrument Co. Hamden, CT). .. Recording electrodes were made from filamented borosilicate glass capillary tubes (inner diameter, 0.84μm) by using a horizontal pipette puller (P-97; Sutter Instrument Co., Novato, CA). ..

    Article Title: Alpha-2 receptor mediates the endogenous antagonistic regulation of itch and pain via descending noradrenaline pathway from the locus coeruleus.
    Article Snippet: Target neurons were recorded using a microscope (FN-S2N, Nikon Corporation, Japan) under IR-DIC visualization and a CCD camera (IR1000E, DAGE MTI, MA, USA). .. Glass pipettes were pulled on a horizontal pipette puller (P-97, Sutter Instruments, CA, USA). ..

    Article Title: ATAD1 Regulates Neuronal Development and Synapse Formation Through Tuning Mitochondrial Function.
    Article Snippet: Cultured rat hippocampal neurons were visualized with 40× water-immersion objective on an upright microscope (BX51WI, Olympus, Tokyo, Japan), with interference contrast (IR/DIC) and an infrared camera connected to the video monitor. .. For whole-cell patch-clamp, patch pipettes were pulled to a resistance of 6–8 MΩ by horizontal pipette puller (P-97, Sutter Instruments, Novato, CA, USA). ..

    Article Title: A new regulation mechanism for KCNN4, the Ca 2+ -dependent K + channel, by molecular interactions with the Ca 2+ pump PMCA4b
    Article Snippet: For quantification, PLA dots per cells were quantified using ImageJ software and compared with control condition: nontransfected HEK293T cells or RBC with only secondary antibodies. .. Glass pipettes (Brand) with final resistance of 3 to 5 MΩ were made on a horizontal pipette puller (P-97; Sutter Instrument). ..



    Similar Products

    90
    Sutter Instrument Company horizontal pipette puller p-97
    Horizontal Pipette Puller P 97, supplied by Sutter Instrument Company, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/horizontal+pipette+puller+p-97/micropipette+puller+p+97/bio_rxiv__2025__07__08__662991-203-21-25
    Average 90 stars, based on 1 article reviews
    horizontal pipette puller p-97 - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    90
    Sutter Instrument Company horizontal pipette puller p- 97
    Horizontal Pipette Puller P 97, supplied by Sutter Instrument Company, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/horizontal+pipette+puller+p-97/micropipette+puller+p+97/pm40408487-300-18-23
    Average 90 stars, based on 1 article reviews
    horizontal pipette puller p- 97 - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    90
    Sutter Instrument Company p-97 horizontal pipette puller
    P 97 Horizontal Pipette Puller, supplied by Sutter Instrument Company, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/horizontal+pipette+puller+p-97/micropipette+puller+p+97/pmc11754434-267-23-25
    Average 90 stars, based on 1 article reviews
    p-97 horizontal pipette puller - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    90
    Sutter Instrument Company the patch 189 pipettes (10-12 mω) were pulled with a horizontal puller (sutter p-97; sutter inst.)
    The Patch 189 Pipettes (10 12 Mω) Were Pulled With A Horizontal Puller (Sutter P 97; Sutter Inst.), supplied by Sutter Instrument Company, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/horizontal+pipette+puller+p-97/the+patch+189+pipettes++10+12+m%CF%89++were+pulled+with+a+horizontal+puller++sutter+p+97++sutter+inst++/pm38984988-68-10-14
    Average 90 stars, based on 1 article reviews
    the patch 189 pipettes (10-12 mω) were pulled with a horizontal puller (sutter p-97; sutter inst.) - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    Image Search Results